Daikin Perfera RXM R Series Service Manual page 165

Split r32
Table of Contents

Advertisement

RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
A
c
A Class 50~71 unit
a Power supply terminal X1M
b Power supply wiring bracket
c Screw (ground wire)
d Indoor unit main PCB
e Switch box screw
f Switch box
2 Route the connectors of the indoor unit fan motor, swing flap motor, swing
raster motor and streamer unit inside the switch box and connect them to the
indoor unit main PCB.
3 Install and tighten the screw to secure the switch box.
4 Install the heat exchanger thermistor in its holder.
5 Attach the wiring harnesses to the switch box as needed.
6 Connect the grounding wire to the heat exchanger using the screw.
7 Connect the power supply wiring to the power supply terminal X1M.
8 Install the power supply wiring bracket. Install and tighten the screw.
Floor standing indoor units
1 install the switch box in the correct location on the indoor unit.
d
f
c
b
a
a Power supply terminal X1M
b Power supply wiring bracket
c Screw (ground wire)
d Plate
a
d
e
b
g
f
3
Components
|
f
e
Service manual