Daikin Perfera RXM R Series Service Manual page 185

Split r32
Table of Contents

Advertisement

To install the swing raster motor
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
a Screw (swing raster motor fixation)
b Swing raster motor
c Gear
9 Remove the swing raster motor from the gear.
10 Disconnect the wiring harness from the swing raster motor.
11 To install the swing raster motor, see
Class 20~42 indoor unit
1 Connect the wiring harness to the swing raster motor.
2 Install the swing raster motor on the correct location on the bracket.
b
c
d
a Rod
b Link
c Screw (swing raster motor fixation)
d Swing raster motor
3 Install and tighten the 2 screws to fix the swing raster motor to the bracket.
4 Guide the rod and link inside the bracket to the correct location.
5 Connect the rod and link to the swing raster motor.
6 Install the swing raster motor assembly on the correct location on the indoor
unit while guiding the rod inside the swing raster compartment.
c
a
b
"Repair
c
a
3
Components
|
a
4
procedures" [
 182].
Service manual