Daikin Perfera RXM R Series Service Manual page 48

Split r32
Table of Contents

Advertisement

3
|
Components
To install the 4-way valve coil
Service manual
48
5 Install the putty (if available) and the insulation (if available) in their original
location.
6 Install the 4‑way valve coil on the 4‑way valve body, see
4
procedures" [
 45].
7 Add refrigerant to the refrigerant circuit, see
1 Install the 4‑way valve coil on the 4‑way valve body.
a
A Class 20~35 unit
a Screw
b 4‑way valve coil
c 4‑way valve body
c
A Class 42~71 unit
a Screw
b 4‑way valve coil
c 4‑way valve body
2 Install and tighten the screw to fix the 4‑way valve coil.
3 Route the 4‑way valve coil harness towards the appropriate PCB.
4 Connect the 4‑way valve coil connector to the PCB.
WARNING
When reconnecting a connector to the PCB, make sure to connect it on the correct
location and do NOT apply force, as this may damage the connector or connector
pins of the PCB.
5 Fix the 4‑way valve coil harness using new tie straps.
"Repair
b
c
A
a
b
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
4
procedures" [
 209].