f
e
a Air thermistor R1T
b Heat exchanger
c Heat exchanger thermistor R2T
d Liquid receiver
e Stop valve with service port (gas)
f Stop valve (liquid)
g 4‑way valve Y1S
h Fan motor M1F
i High pressure switch S1PH
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
RXM42~71R + ARXM50~71R
a
b
r
c
d
h
i
q
m
p
j Main PCB A1P
k Power supply terminal X1M
l Muffler
m Expansion valve Y1E
n Muffler with filter
o Accumulator
p Compressor M1C
q Discharge pipe thermistor R3T
r Fan
6
Technical data
|
j
k
l
m
n
m
o
Service manual
243