Daikin Perfera RXM R Series Service Manual page 176

Split r32
Table of Contents

Advertisement

3
|
Components
To install the swing flap motor
To remove the swing flap motor wiring harness
Service manual
176
1 Connect the wiring harness to the swing flap motor.
2 Install the swing flap motor on the correct location on the indoor unit. Make
sure the swing flap motor shaft is correctly inserted in the link.
a
b
a Main swing flap
b Secondary swing flap
c Screw (swing flap motor fixation)
d Swing flap motor
3 Install and tighten the screw to fix the swing flap motor.
4 Install the secondary swing flap in the indoor unit (by clicking it on).
5 Install the main swing flap in the indoor unit (by clicking it on).
6 Install the switch box, see
Is the problem solved?
Yes
No
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Remove the swing flap motor, see
INFORMATION
The swing flap motor wiring harness is also connected to the swing raster motor.
2 Put a small drain pan (or container) under the drain hose.
3 Remove the screw from the fixation bracket and pull the drain hose
downwards to remove it from the indoor unit.
c
d
4
"3.14 Plate
work" [
 151].
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.
"3.14 Plate
"Repair
procedures" [
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
4
work" [
 151].
4
 175].
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents