Repair procedures
To remove the swing flap motor
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
Pins
2-3
2-4
2-5
3-4
3-5
4-5
Swing flap motor resistance
measurements are correct?
Yes
No
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Remove the switch box, see
2 Remove the swing flap from the indoor unit (by clicking it out).
3 Remove the 2 screws that fix the swing flap motor.
a Swing flap
b Screw (swing flap motor fixation)
c Swing flap motor
d Coupling piece
4 Remove the swing flap motor and coupling piece.
5 Remove the spring and remove the coupling piece from the swing flap motor.
6 Disconnect the wiring harness from the swing flap motor.
7 To install the swing flap motor, see
Measured resistance (Ω)
706.8~813.2
Action
Replace the swing flap motor wiring
harness, see
"Repair
4
procedures" [
Replace the swing flap motor, see
"Repair
procedures" [
"3.14 Plate
4
"3.14 Plate
work" [
 151].
a
d
b
c
b
"Repair
procedures" [
3
Components
|
 179].
4
 179].
4
work" [
 151].
4
 179].
Service manual