Components
To check the HAP LED of the main PCB
Service manual
124
Prerequisite: Remove the required plate work, see
1 Turn ON the power of the unit.
2 Measure the voltage between the black and white wires.
Result: The measured voltage MUST be 230 V AC.
a Black wire
b White wire
Is the measured voltage on the PCB
correct?
Yes
No
3 Check the power supply to the unit, see
Does the unit receive power?
Yes
No
Prerequisite: First check the power supply to the main PCB, see
4
procedures" [
 123].
1 Locate the HAP LED on the main PCB.
"3.14 Plate
work" [
a
b
Action
Return to
"Checking
4
procedures" [
 123] of the PCB and
continue with the next procedure.
Continue with the next step.
"Checking
procedures" [
Action
Replace the main PCB, see
4
procedures" [
 131].
Adjust the power supply to the unit, see
4
"Repair
procedures" [
 203].
a
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
4
 151].
4
 202].
"Repair
"Checking
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01

Hide quick links: