Daikin Perfera RXM R Series Service Manual page 84

Split r32
Table of Contents

Advertisement

3
|
Components
To install the expansion valve motor with clip
Service manual
84
INFORMATION
The expansion valve and motor can have a different configuration / layout.
5 Reinstall the putty.
A
a
a
a
a
A Class 20~35 unit
a Putty
b Expansion valve pipe
c Expansion valve body
A
a
A Class 42~71 unit
a Putty
b Expansion valve pipe
c Expansion valve body
6 Reinstall the putty.
7 To install the expansion valve motor, see
8 Add refrigerant to the refrigerant circuit, see
1 Install the expansion valve motor on the expansion valve body.
INFORMATION
The expansion valve motor is equipped with a pipe retention clip. Install the pipe
retention clip over the pipe to lock the expansion valve motor.
c
b
c
b
"Repair
procedures" [
"Repair
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
4
 79].
4
procedures" [
 209].
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01

Hide quick links:

Advertisement

Table of Contents
loading