Daikin Perfera RXM R Series Service Manual page 184

Split r32
Table of Contents

Advertisement

3
|
Components
Service manual
184
Class 50~71 indoor unit
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Remove the switch box, see
2 Put a small drain pan (or container) under the drain hose.
3 Remove the screw from the fixation bracket and pull the drain hose
downwards to remove it from the indoor unit.
a Screw (drain hose)
b Drain hose
4 Remove the swing raster motor cover.
d
e
a Swing raster motor cover
b Swing raster motor assembly
c Screw (swing raster motor assembly)
d Fan guard
e Swing raster motor rod
5 Remove the 2 screws that fix the swing raster motor assembly to the indoor
unit.
6 Disconnect the swing raster motor rod from the swing raster shaft.
7 Remove the swing raster motor assembly from the indoor unit.
8 Remove the 2 screws that fix the swing raster motor to the bracket.
"3.14 Plate
"3.14 Plate
work" [
4
 151].
b
a
c
b
a
c
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
4
work" [
 151].
FVXM25~50A
Split New Perfera R32