RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
a Screw (drain hose)
b Drain hose
4 Remove the 2 screws that fix the swing raster motor assembly to the indoor
unit.
c
d
a Screw (swing raster motor assembly)
b Swing raster motor assembly
c Fan guard
d Swing raster motor rod
5 Remove the fan guard.
6 Disconnect the swing raster motor rod from the swing raster shaft.
7 Remove the swing raster motor assembly from the indoor unit.
8 Disconnect the rod and link from the swing raster motor. Keep the rod and
link for reuse.
b
c
d
a Rod
b Link
c Screw (swing raster motor fixation)
d Swing raster motor
9 Remove the 2 screws that fix the swing raster motor to the bracket.
10 Remove the swing raster motor.
11 Disconnect the wiring harness from the swing raster motor.
12 To install the swing raster motor, see
a
b
c
a
"Repair
3
Components
|
a
4
procedures" [
 182].
Service manual
183