CoolSmart TV - Combustible "Over-Facing" (Optional)

When using the CoolSmart TV kit, Combustible material can be installed over the non-combustible board on the
front of the fireplace. To be clear, there will be (2) layers of board over the front of the appliance, one non-
combustible that covers the entire front of the fireplace, and a second layer that can be combustible material
that is placed on top of the non-combustible board.
The combustible material MUST be installed OVER 1/2" of non-combustible board.
NOTE:
The maximum facing depth (combustible + non-combustible facing) is 1-1/4". Any facing that extends
farther than 1-1/4" must meet mantel clearances.
WARNING: The front of the appliance is subject to high temperatures which may cause discoloration and/or
material degradation. Take this into account when choosing finishing materials.
Installation With Thick Facing Guide (facing butts thick facing guide) - STANDARD
NOTE:
Leave the thick facing guide in
place on the fireplace.
NOTE:
The screen assembly mounts
should be left in the stock position
(all the way in).
Installation Without Thick Facing Guide (screen assembly overlaps facing)
Note:
Remove the thick facing guide on
the fireplace (it is not used with this
configuration).
Note:
The screen assembly mounts will
need to be moved out to
accommodate the thickness of the
facing (see installation manual for
details).
Warning:
When not using the thick facing guide, a
3/16" (4.8mm) air space is required from
all four sides of the tile stop on the
fireplace to the combustible facing (see
details below).
© Travis Industries
Installation
(for qualified installers only)
WARNING
Combustible Facing
Allowed
Non-Combustible board
Non-Combustible
Facing Only
Screen Assembly
Combustible Facing
Allowed
Non-Combustible board
Non-Combustible
Facing Only
Screen Assembly
4/19/23 - 1453
OVER
Max Depth
1-1/4" (32mm)
Fireplace side
Th
Thick Facing
Guide
Tile Stop
OVER
Combustible Facing
Fireplace side
Tile Stop
PB 42 & 54 MV/GSB2/GSR2 Install
Combustible
Facing
Required
3/16" (4.8mm)
Air Space

Advertisement