25.0

Installer Keypad

The Installer Keypad must be set to Address
0 (set MODE to OFF) and the Installer Switch
must be closed to program the control panel
from the Installer's Keypad.
Use the color-coded keypad wire assembly supplied
with the control panel to connect the Installer Keypad
to the panel's Aux/Data pins. See Figure 57 .
DS7447E/DS7447V2

Figure 57: Installer Keypad Wiring

26.0

Installer Mode

Use of the Installer PIN might be restricted.
See "Keypad Response Options" in the
DS7200V2 Expert Programming Guide
(P/N: 4998153891) for information on
enabling/restricting the Installer PIN.
When all areas configured in the control panel are
disarmed, the Installer Menu can be accessed from
any LCD keypad by entering [Installer PIN][#][4][1] or
[#][4][1][Installer PIN].
The default Installer PIN is 7890.
Close the Installer Switch must when using an
Installer Keypad.
If any area configured in the control panel is armed,
only the Installer Keypad can access the Installer
Menu. After 20 minutes of inactivity, the Installer
Menu is automatically exited. The control panel resets
if it was in programming mode.
If the Installer Switch is closed when the control panel
powers up, the control panel completes its power up.
It then checks if there is an Installer Keypad. If not, it
finds the text keypad with the lowest address. The
first keypad found is placed in the Installer Menu with
installer rights, and the 20-minute timer is started.
If [8] is pressed to enter keypad programming, the
control panel enters keypad programming even if
keypad programming is disabled. When the Installer
Menu is exited, the control panel reverts to normal
operation.
DS7200V2-UK Installer's Guide
Control Panel
Red (+)
Black (-)
Green
Yellow
BATT+
BATT-
Copyright  2007 Bosch Security Systems, Inc.
27.0

Installer Menu

The Installer Menu consists of the following choices
(the numbers preceding the descriptions represent
the keypad number key to press):
• 1: Bell Test
• 2: Strobe Test
• 3: Battery Test
• 4: Test Report
• 5: Zone Status
• 6: Output Test
• 7: RF Menu
• 8: Keypad Program
• 9: Program Key (PK32)
• 0: Call for Service
The following sections explain each menu choice.
27.1

Bell Test

Press the [1] key to begin a Bell Test.
The control panel activates the Bell Time (Output
Function Type 1|5) and Alarm Output (Output
Function Types 1|8 to 1|12) functions for three
seconds.
For a complete description of output functions, see
Outputs on page 86.
27.2

Strobe Test

Press the [2] key to begin a Strobe Test.
The control panel activates the Strobe Output
functions and waits for the installer to press the [#]
key to end the test. If the installer fails to press [#]
with 20 minutes, the control panel automatically
terminates the strobe test.
27.3

Battery Test

Press the [3] key to begin a Battery Test.
The battery test causes the system to run on battery
for 4 minutes. If the battery voltage falls below 12.1
volts during the 4-minute test, or if the battery is
missing, the system restores AC power and displays
a system trouble at all keypads.
27.4

Test Report

Press the [4] key to send a test report.
The control panel attempts to send a test report. If
there is a system trouble at the time of the test, the
control panel sends a "Test, Off Normal" report.
If the test communication is unsuccessful, the control
panel creates a system trouble and a communication
failure.
PART II: SYSTEM INSTALLATION AND SETUP
P/N: 4998152533-02
Page 33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds7220v2Ds7240v2

Table of Contents