44.0

Global Output Configuration

The DS7240V2 supports Outputs 1-20: four on-board Programmable Outputs (PO 1 to PO 4), and up to 16 off-board. The
DS7220V2 supports Outputs 1-12: four on-board Programmable Outputs (PO 1 to PO 4), and up to 8 off-board.
Outputs 5 through 12 are available on an off-board Data Bus device (DX3010 Octo-Output Expander or DX3020 X-10 Control
Module) at Data Bus Address 150.
Outputs 13 through 20 (DS7240V2 only) are available on an off-board Data Bus device (DX3010 Octo-Output Expander) at
Data Bus Address 151.
Global Output Options
• Address: 1039
• Default: 5
• Selections: 0-15
Global Output Options
No Options Selected
Output 2 is Supervised Horn/Strobe Speaker Output
Send Output Set/Reset Reports
Enable Strobe Arming Flash to indicate RF Keyfob &
Keyswitch Arm/Disarm
Enable Alarm Output Arming Beep to indicate RF Keyfob &
Keyswitch Arm/Disarm
This parameter affects all programmable outputs.
• Output 2 Is Supervised Horn/Speaker Output: This option turns Programmable Output 2 (PO 2) into a supervised siren
driver. If a siren or speaker is not connected, the control panel generates a Siren Trouble event that can include a Siren
Trouble {193} report. The restoral event is reported with Siren Trouble Restore {194}. See On-board Output Setup on page
16 for more information. Compatible speakers include D118 and D119 Speaker Drivers.
• Send Output Set/Reset Reports: This option allows the control panel to send Output Set {109 to 111} and Output Reset
{106 to 108} reports when outputs are operated by a user, a Sked or RPS (Remote Programming Software).
• Enable Strobe Arming Flash to Indicate RF Keyfob and Keyswitch Arm/Disarm: This option allows the Strobe Output
Function (1|6) to indicate RF and keyswitch arming and disarming as follows:
− 3 seconds = transition to Off (disarmed)
− 6 seconds = transition to All On or Perimeter Only
• Enable Alarm Output Arming Beep to Indicate RF Keyfob and Keyswitch Arm/Disarm: This option allows any Alarm
Output Functions (1|8, 1|9, 1|10, and 8|8) to indicate RF and Keyswitch arming and disarming as follows:
− 1 Beep = transition to Off (disarmed)
− 2 Beeps = transition to All On
− 3 Beeps = transition to Perimeter Only
The "Enable Alarm Output Arming Beep to Indicate RF Keyfob and Keyswitch Arm/Disarm" option is
only available for RF Keyfobs (not RF Keypads) and when arming from RPS or a keyswitch.
Page 84
P/N: 4998152533-02
PART IV: CONTROL PANEL PROGRAMMING
0
Copyright  2007 Bosch Security Systems, Inc.
Enter This Data Digit to Select Options
1
2
3
4
5
6
7
8
• •
• •
• • • •
• • • • • • • •
9 10 11 12 13 14 15
• •
• •
• • • •
DS7200V2-UK Installer's Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds7220v2Ds7240v2

Table of Contents