5.4.1

Selection of Program and Weld timer

1070 080 037-101 (99.01) GB
BT220 Technical Information and Operation
In order to display or change the data of a program stored on a connected
weld timer (TIM) via the BT220, you must select both the relevant timer
number and the relevant program number.
Values between "0" and "255" are admissible for input as program numbers.
The possible timer numbers depend on the number of timers actually con-
nected and start with "1". Depending on the BT220 version used the follow-
ing assignment applies:
BT220-1 without STK multi-contact
interface board:
BT220-2 without STK multi-contact
interface board:
BT220-x with STK multi-contact
interface board
Remarks
-
Please note that channel 4 of the multi-contact interface board is always
used for communication with the BT220!
-
Numbers of timers not connected (TIMx) are not recognized on selection
and not accepted.
In the following description of the operating sequence we assume that the
BT220 is in the Main Menu of the function key mode (see page 5-6).
= press corresponding key
x
Change pro-
gram or weld
timer number
VAR
Fig. 5-4:
Operating Sequence: Selection of Program and Weld timer
TIM1 = Timer at X4
TIM1 = Timer at X4
TIM2 = Timer at X5
TIM1 = Timer at Channel 1
TIM2 = Timer at Channel 2
TIM3 = Timer at Channel 3
TIM4 = Timer at Channel 5
TIM5 = Timer at Channel 6
TIM6 = Timer at Channel 7
TIM7 = Timer at Channel 8
0
"
.
.
A
9
Select "Pro-
Enter pro-
gram" or
"TIM" (weld
gram or
weld timer
timer)
number
Operation
Cancel
inputs
MEN
Accept inputs
5-7