History Log; Figure 61: History Log Display; Table 45: History Log Display Descriptions; Table 46: History Log Communication Status Values - Bosch DS7200V2-UK Installer's Manual

Table of Contents

Advertisement

62.0

History Log

The history log can store up to 254 events. When the log reaches its threshold, the control panel sends a Log Threshold {85}
report. When the Log reaches capacity, the system sends a Log Overflow {84} report to the Security Company. See Log
Supervision Configuration on page 50.
RPS can accept a download from the control panel's log, thus clearing the log file. If the log is not cleared it begins writing over
previous events.
The first line of the log shows the event description (see Control Panel Events and Reporting Formats on page 124). The
second line of the log display alternates between the time and date of the event and the area, zone (device), user and
communication information for the event. The control panel displays time in 24-hour format and the date as programmed in the
Date Format and Enable PIN Trouble parameter. See "Date Format and Enable PIN Trouble" in the DS7200V2 Expert
Programming Guide (P/N: 4998153891).
To view the log, press [#][8][5]. The keypad might prompt you to enter a valid PIN. Press the [*] key to advance to the next
event. Press [#] to exit the log and return to the normal display. The history log uses the following characters to communicate
certain information:
The following table defines the communication status values that may appear in the history log:
Value
A
Aborted
D
Deleted from pending buffer by control panel
reboot
F
Failed
L
Local
P
Pending
S
Sent
Figure 61 is a DS7447E/DS7447V2 Keypad display of an event log. The first line describes the event and the second line
alternates between event specific information (such as area # and zone #, if applicable) and the time and date of the event.
DS7200V2-UK Installer's Guide
Display
A#
Zn##
Dv##
Ln##
Mn#
Cd##
Op##
Ks##
U##
##
Communication status for Routing

Table 45: History Log Display Descriptions

Description

Table 46: History Log Communication Status Values

Event
Sensor Mon Rstl
A1 Zn3
SL
Destination 2
Event Specific
Information
Destination 1

Figure 61: History Log Display

Copyright  2007 Bosch Security Systems, Inc.
Description
Area Number
Zone Number
Device Number
Phone Line Number
Minutes till Auto Arm Sked
User Code Number
Output Number
Keyswitch Number
User Number
Destinations 1 & 2
An alarm event was programmed with an event abort
window and the control panel was silenced before the
abort timer had expired. The keypad emits a quick three-
chirp tone if an event report is aborted when the control
panel is silenced.
The control panel was rebooted before the events could
be sent.
The event could not be sent to the specified destination.
The problem may be either at the receiver end or with
the control panel programming.
The event is not programmed to report to any remote
destination.
The event is waiting to be sent to the ARC.
The event was successfully sent.
Event
Sensor Mon Rstl
08:29 13/06/01
Time of Event
Probable Cause
Date of Event
P/N: 4998152533-02