Table 1: Terminal Descriptions - Bosch DS7200V2-UK Installer's Manual

Table of Contents

Advertisement

Term
Silkscreen Label
1,2
18 VAC
3
Earth Ground Symbol
4
Data, Grn (Green)
5
Data, Yel (Yellow)
6,7
Aux Power 12 VDC (-)
8,9
Aux Power 12 VDC (+)
Aux/Data (RYGB)
Red (Batt +)
Black (Batt -)
10
PO 4
11
PO 3
12
PO 2
13
Alrm +
14
PO 1, A
15
PO 1, B
16
SMK +
17
L-1
18
Com
19
L-2
20
L-3
21
Com
22
L-4
23
L-5
24
Com
25
L-6
26
L-7
27
Com
28
L-8
29
T
30
T1
31
R1
32
R
PO 1 SELECT
Auxiliary
Page 2
P/N: 4998152533-02
18 V, 50 VA; #18 AWG (1.2 mm), Stranded.
Earth Ground.
Data Bus data on Terminals 4 & 5. Panel supports up to 305 m of #22 AWG (0.8 mm) wire on
these terminals (any configuration).
Terminals 6-9 are auxiliary power. 1.2 A. Include any programmable outputs (PO 1 to PO 4) not
configured for alarm output. PTC suppressed.
4-pin connector to Data Bus and auxiliary power. Use to connect an installer keypad for keypad
programming.
Battery (+) spade.
Battery (-) spade.
Programmable Outputs 3 & 4, up to 500 mA (-). Include in Aux Power calculations for all except
"Alarm" output functions. PTC suppressed.
Programmable Output 2. 500 mA (-).Include in Aux Power calculations for all except "Alarm"
output functions. Supervised for Horn/Speaker alarm function. PTC suppressed.
Alarm power. Up to 1,850 mA. PTC suppressed. Provides power for supervised siren driver (PO
2) and Alarm Output (PO 1, A).
Jumper sets PO 1 terminals A (14) and B (15) for "dry" Form "A" contact or for Alarm Output
(using PO 1, A as negative (-) terminal).
Not used.
Sensor Loop 1. Wire length for Sensor Loops 1 to 8 are limited only by the resistance on the loop
and potential EMI problems. Resistance must be < 100 Ω with EOL resistor shorted and detection
devices connected.
Common for Sensor Loops 1 and 2.
Sensor Loop 2 input.
Sensor Loop 3.
Common for Sensor Loops 3 & 4.
Sensor Loop 4.
Sensor Loop 5.
Common for Sensor Loops 5 & 6.
Sensor Loop 6.
Sensor Loop 7.
Common for Sensor Loops 7 & 8.
Sensor Loop 8.
Connections for incoming phone lines.
Connections for premises devices such as telephones.
Connections for premises devices such as telephones.
Connections for incoming phone lines.
Configures PO 1 for Form "A" relay or Alarm Output.
Auxiliary Module and/or Programming Key (PK32) Header.

Table 1: Terminal Descriptions

Copyright 2007 Bosch Security Systems, Inc.
Description
DS7200V2-UK Installer's Guide