52.0

Tamper Response Configuration

Tamper Alarm/Trouble Options
• Address: 3406
• Default: 1
• Selections: 0-7, 12-15
Tamper Alarm/Trouble Options
No Tamper Alarms, no Trouble or Restoral Reports
Tamper Alarm when Armed (Set)
Tamper Alarm when Disarmed (Unset)
Send Tamper Trouble Reports
Send Tamper Trouble Restoral Reports
This parameter configures the control panel's response when tamper alarms occur, and whether tamper trouble and tamper
trouble restoral reports are sent. This is a global parameter that applies to both zone and non-zone tampers, system tampers,
and device tampers. It does not include user tampers.
• Tamper Alarm when Armed (Set): If this option is enabled, a tamper condition that occurs when the control panel is armed
creates a tamper alarm response. If this option is disabled, a tamper condition that occurs when the control panel is armed
creates a tamper trouble condition.
When the control panel is armed Perimeter Only or Part On, only some of the controlled zones can create an alarm. If this
option is selected and the zone that is tampered is a Perimeter Only or Part On zone, a tamper alarm is created. If the zone
is not a Perimeter Only or Part On zone, the tamper response depends on the setting made for the next option (Tamper
Alarm when Disarmed). The non-zone tampers are always included in the Perimeter Only or Part On zones and would
create a tamper alarm if tampered.
• Tamper Alarm when Disarmed (Unset): If this option is enabled, a tamper condition that occurs when the control panel is
disarmed creates a tamper alarm response. If this option is disabled, a tamper condition that occurs when the control panel
is disarmed creates a tamper trouble condition.
If the control panel is armed Perimeter Only or Part On, the zones that are excluded from the controlled zones respond to the
tamper condition as defined by the setting of this option.
• Send Tamper Trouble Reports: If this option is enabled, a tamper report {3} is sent to the ARC when a tamper trouble (not
alarm) occurs. If this option is disabled, no report is sent.
• Send Tamper Trouble Restoral Reports: If this option is enabled, a tamper restoral report {112} is sent to the ARC when a
tamper trouble restores. If this option is disabled, no report is sent.
DS7200V2-UK Installer's Guide
0
Copyright  2007 Bosch Security Systems, Inc.