Self-Contained Control
EN
Panel

Advertisement

Table of Contents
loading

Summary of Contents for Bosch DS12R

  • Page 1 DS12R Installation and Operation Guide Self-Contained Control Panel...
  • Page 2 DS12R | Installation and Operation Guide | Trademarks Trademarks ® Microsoft is a registered trademark of Microsoft Corporation in the United States and/or other countries. Bosch Security Systems, Inc. | 5/08 | F01U081956-01...
  • Page 3: Table Of Contents

    DS12R | Installation and Operation Guide | Contents Contents Overview ................................4 Multi-Tenant System (MTS) Overview......................4 MTS Device Address............................4 DS12R Overview ..............................4 Installation................................6 Mounting the DS12R............................6 Wiring the DS12R..............................7 2.2.1. System Wiring ............................... 7 2.2.2.
  • Page 4: Overview

    DS12R | Installation and Operation Guide | Overview Controller Area Network (CAN) wiring requirements 1.0 Overview are as follows: • CAN Bus Interface: Connect the CAN bus to the Multi-Tenant System (MTS) Overview MTR Communication Receiver with at least MTS is a distributed security system for monitoring 1.5 mm (16 AWG) shielded twisted-pair wire;...
  • Page 5 DS12R | Installation and Operation Guide | Overview Figure 1: MTS System Overview 1- MTSW Security Station Software 5- MTGW CAN RS-485 Bus Gateway 2- MTR Communication Receiver 6- RS-485 Device (DS12R is shown) 3- CAN Bus 1 7- RS-485 Device (DS6R2 is shown) 4- CAN Bus 2 Bosch Security Systems, Inc.
  • Page 6: Installation

    Figure 3: Mounting Holes Mounting the DS12R You can mount the DS12R directly onto the intended surface (flush or semi-flush), or you can mount it on an electrical box. 1. To open the keypad, use a screwdriver to press the release tabs on the bottom of the keypad.
  • Page 7: Wiring The Ds12R

    Zone 1 DS12R. Common (earth ground) Zone 2 Connect devices as shown in Figure 4. If the DS12R is Zone 3 the last device on the RS-485 bus, connect a 120 Ω Common (earth ground) end-of-line (EOL) resistor in parallel with the Zone 4 RS-485.
  • Page 8: Input Wiring

    DS12R | Installation and Operation Guide | Installation 2.2.2. Input Wiring Figure 8: Smoke Detector with EOL Relay Module Typical Zone Wiring The DS12R supports zones wired with normally-open (NO) or normally-closed (NC) contacts. Terminate each zone with a 47 kΩ EOL resistor. Refer to Figure 6.
  • Page 9: Output Wiring

    2.2.3. Output Wiring Refer to Figure 12. The DS12R has Form C (NO/C/NC) contacts rated for 3 A at 28 VDC. Figure 12: Wireless Receiver Wiring Two solid-state current sinks can be used for devices with a current draw of up to 250 mA for each device.
  • Page 10: Programming

    Use the Master Code for programming. The three User Codes cannot be used to program the DS12R. The default Master Code is 1234. If you forget the Master Code, reset the DS12R to its default values. Refer to Section 3.6 Resetting Default Values on page 17 Entering Programming Mode 1.
  • Page 11 1 Refer to Table 4 on page 15 for descriptions of the zone types. 2 The DS12R has only one Entry Delay Timer and One Exit Delay timer. Any zone programmed to “Delay” follows these timers. Bosch Security Systems, Inc. | 5/08 | F01U081956-01...
  • Page 12 1 Refer to Table 4 on page 15 for descriptions of the zone types. 2 The DS12R has only one Entry Delay Timer and one Exit Delay timer. Any zone programmed to “Delay” follows these timers. 3 If a zone is programmed to 24-hour, bypass is not allowed.
  • Page 13 This code must be unique. 6 If an RF ID is entered for Addresses 57 to 80, the zone is a wireless zone. The DS12R ignores the wired zone. Bosch Security Systems, Inc. | 5/08 | F01U081956-01...
  • Page 14 000000000 = Disabled (zone is hard wired) Allows 000000001 to 999999999 ID numbers 1 If an RF ID is entered for Addresses 57 to 80, the zone is a wireless zone. The DS12R ignores the wired zone. Bosch Security Systems, Inc. | 5/08 | F01U081956-01...
  • Page 15 Silent Zone When the system is armed, faulting a Silent zone causes a Silent alarm. The keypad is silent and shows no alarm output, but the DS12R sends an alarm event to the central station. Perimeter Zone When the perimeter is armed, faulting a Perimeter zone causes an alarm.
  • Page 16: Programming Wireless Devices

    167770187 Receivers. Mount the receivers up to 20 m (65.7 ft) from the DS12R. 16 7770187 The DS12R supports up to 6 key fobs and 24 wireless 16 7770 18 7 devices, including motion detectors, smoke detectors, 167770187 and door contacts.
  • Page 17: Resetting Default Values

    DS12R | Installation and Operation Guide | Programming Resetting Default Values Configuring the Working Mode The DS12R can be used as stand-alone system or as a 3.6.1. Reset the Master Code component of an MTS system. Warning: Remove power from all devices 3.7.1.
  • Page 18: Wireless Maintenance

    DS12R | Installation and Operation Guide | Wireless Maintenance 4.0 Wireless Maintenance Low Battery Trouble Wireless Device Test Mode The DS12R beeps twice every minute when it receives a low battery signal from the wireless receiver. The Disarm the system before using Test LED for the zone with the low battery condition flashes Mode.
  • Page 19: Rs-485 Bus Address

    DS12R | Installation and Operation Guide | RS-485 Bus Address 6.0 RS-485 Bus Address Assign a unique address to each device connected to the RS-485 bus. DIP Switch Number DIP Switch Number DIP Switch Number • = DIP switch ON •...
  • Page 20 Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450-9199 USA www.boschsecurity.com © 2008 Bosch Security Systems, Inc. F01U081956-01...