47.0

RF Receiver Configuration

Premises RF Receiver Options
• Address: 1249
• Default: 0
• Selections: 0-7
Premises RF Receiver Options
No RF Receiver Connected
RF Receiver 1 connected, set to Address 50
RF Receiver 2 connected, set to Address 51
Disable RF Loop Tamper
Keyfobs Do Not Force Arm Faulted Zones
• Receiver 1 Connected, Set Receiver to Address 50: Enable this option if RF Receiver 1 is connected to the control panel.
Set the RF receiver's address to 50 (jumper setting OFF). See Adding RF ID Codes on page 34 for instructions. See RF
Transmitters and Zone States on page 75 for details on RF transmitters and zone states.
All status reports for the RF Receiver include the address. For example, if the cover is removed, Event {127} (DBus Tamper)
is generated.
• Receiver 2 Connected, Set Receiver to Address 51: Enable this option if RF Receiver 2 is connected to the control panel.
Set the RF receiver's address to 51 (jumper setting ON). See Adding RF ID Codes on page 34 for instructions. See RF
Transmitters and Zone States on page 75 for details on RF transmitters and zone states.
All status reports for the RF Receiver include the address. For example, if the cover is removed, Event {127} (DBus Tamper)
is generated.
• Disable RF Loop Tamper: The RF3401E transmitter's loop can be wired with a single 2.2 k EOL resistor, or it can be wired
with dual 2.2 k EOL resistors. If this option is enabled, wire the RF3401E with a single 2.2 k EOL resistor. The loop can
report as normal, shorted, or open. If this option is disabled, wire the RF3401E is with dual 2.2 k EOL resistors. The loop can
report as normal, shorted, faulted, or open.
• Keyfobs Do Not Force Arm Faulted Zones: If this option is enabled, arming from a keyfob does not force arm faulted
zones. A faulted zone prevents the area from arming. If this option is disabled, arming from a keyfob does force arm faulted
zones.
Page 98
P/N: 4998152533-02
PART IV: CONTROL PANEL PROGRAMMING
0
Copyright  2007 Bosch Security Systems, Inc.
Enter This Data Digit to Select Options
1
2
3
4
5
6
7
8
• •
• •
• • • •
• • • • • • • •
9 10 11 12 13 14 15
• •
• •
• • • •
DS7200V2-UK Installer's Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds7220v2Ds7240v2

Table of Contents