Figure 60: Routing Destination Phone Number Configured For Basic Pager; Table 41: Format Field Options - Bosch DS7200V2-UK Installer's Manual

Table of Contents

Advertisement

All information the control panel needs to format and send events to a pager is contained in the Phone Number 1 (2) for
Destination 1 (2) parameter (see page 42). Figure 60 shows the phone number broken into fields.
1-
Digits to Dial Field: Enter the phone number for the paging service followed by any special characters required (a
pause, for example). See Table 42 for phone number entries.
2-
Field Terminator: Every field must end with the terminator digit, always 0 (zero).
3-
Format Field: Use this field to configure how the message appears in the pager's display. See Table 41 for Format
Field options.
4-
Field Terminator: Every field must end with the terminator digit, always 0 (zero).
5-
End Page Field: Enter the digits that tell your paging service you are done sending your page.
6-
Field Terminator: Every field must end with the terminator digit, always 0 (zero).
The control panel dials the number you enter in the Digits to Dial Field to contact the paging service. Add one or more
pauses at the end of the number to allow the paging service time to answer the phone and prepare to accept the message.
The Digits to Dial Field ends with a Field Terminator (0).
The Format Field follows the Digits to Dial Field . It defines what information follows the account number in the paging
message. The Format Field ends with a Field Terminator (0).
The End Page Field follows the Format Field . The digits you enter in this field are sent after the paging message. For many
paging services, a '#' indicates the end of the end of the paging message. The End Page Field ends with a Field Terminator
(0).
You must enter the pauses required for the paging service in the Digits to Dial Field before the Digits to
Dial field terminator.
The number of pauses required varies based on the paging service.
Test the pager to determine that you entered enough pauses to establish communications to the
paging service.
If the zone/user number is three digits, the leading digit is omitted. For example, "252" displays as "52."
Do not use alpha characters for the account number in basic pager format.
Page 110
P/N: 4998152533-02
PART IV: CONTROL PANEL PROGRAMMING
5 5 5 1 2 3 4 P P
1

Figure 60: Routing Destination Phone Number Configured for Basic Pager

Format Field
Empty
Account, Event, Area, and Zone Numbers
with separator characters
#
Account, Event, Area, and Zone Numbers
without separator characters
***
Account, Event, and Area Numbers with
separator characters
#***
Account, Event, and Area Numbers without
separator characters
**
Account and Event Numbers with separator
characters
#**
Account and Event Numbers without
separator characters
*
Account Number only

Table 41: Format Field Options

Copyright  2007 Bosch Security Systems, Inc.
0
* * *
0
2
3
4
Resulting Pager Display
1234-008-03-21
12340080321
1234-008-03
123400803
1234-008
1234008
1234
# 9
0
5
6
DS7200V2-UK Installer's Guide