Copying Cross-Point Assign Tables; Selecting Cross-Point Assign Tables; Exporting Source Names And Destination Names; Assigning The [Side Flag] Button - Sony XVS Series User Manual

Multi format switcher system with icp-x7000 integrated control panel
Hide thumbs Also See for XVS Series:
Table of Contents

Advertisement

Copying Cross-Point Assign Tables

You can copy the contents of a cross-point assign table to
another cross-point assign table.
Note
The contents of tables 1 to 14 cannot be copied to the main
table.
1
In the Engineering Setup >Panel >Xpt Assign menu
(7322), press [Table Copy].
The Table Copy menu (7322.8) appears.
2
Select the copy source and copy destination tables.
3
Press [Copy].
4
Check the message, then press [Yes].

Selecting Cross-Point Assign Tables

You can select the cross-point assign table to use for each
of the banks or buses.
Note
It is not possible to assign cross-point assign tables 5 to 14
to a bus of a switcher operated by an MKS-8080/8082
AUX Bus Remote Panel.
1
In the Engineering Setup >Panel >Xpt Assign menu
(7322), select the target bank or bus to set.
2
Select the table to assign.
3
Press [Table Assign Set].
Exporting Source Names and
Destination Names
You can send the source names and destination names to
the S-Bus.
1
In the Engineering Setup >Panel >Xpt Assign menu
(7322), press [Name Export].
The Name Export menu (7322.9) appears.
2
Set the destination station ID.
No.
Parameter Adjustment
1
Station ID
Station ID setting
a) If set to 255, the names are sent to all stations ("All" is displayed in
3
Press [Src Name Export].
The source names are exported to the station set in step
2.
4
Press [Dest Name Export].
The destination names are exported to the station set in
step 2.
Destination names cannot be specified arbitrarily, so
fixed names are used.

Assigning the [SIDE FLAG] Button

You can assign the [SIDE FLAG] button to the right hand
edge of the cross-point button row for enabling and
disabling side flags. The settings are common to the M/E
and PGM/PST banks.
Assigning the [SIDE FLAG] button moves the [SHIFT]
button one space to the left.
Note
If a macro attachment is set for the button, assigning the
side flag button shifts the number of the button, so pressing
the button will no longer execute the macro. The settings,
however, are maintained, so that when you cancel the side
flag assignment, the macro can be executed once more.
SHIFT button moves one space to the left
For details about side flags, see "Side Flags" (page 179).
1
a)
In the Engineering Setup >Panel >Xpt Assign menu
(7322), press [Side Flags Button Assign].
381
the status area).
Note
SIDE FLAG button
Cross-point control block

Advertisement

Table of Contents
loading

Table of Contents