Kyocera ECOSYS M2135dn Service Manual page 495

Hide thumbs Also See for ECOSYS M2135dn:
Table of Contents

Advertisement

Connector access point
YC2: PF paper feed clutch, PF conveying clutch
YC4: PF conveying motor
YC5: Main/Engine PWB
YC6: PF main PWB (Lower cassette)
YC7: PF feed sensor
Connec-
Pin
tor
YC2
1
+24V6FB
2
FEEDCLN
3
+24V6FB
4
TRNSCLN
YC4
1
TMOTRDYN
2
TMOTCLK
3
TMOTDRVN
4
GND
5
+24V6
YC5
1
GND
2
+3.3V4
3
+3.3V2
4
PFINT
5
PFRDY
6
PFSEL0
7
PFSEL1
8
PFCLK
9
PFTXD
10
PFRXD
11
+24V6FB
12
+24V6FB
13
GND
YC6
1
GND
2
+3.3V4
3
+3.3V2
4
PFINT
5
PFRDY
6
PFSEL0
7
PFSEL1
8
PFCLK
9
PFTXD
10
PFRXD
Signal
I/O
O
24 V DC
O
0/24 V DC
O
24 V DC
O
0/24 V DC
I
0/3.3 V DC
O
0/5 V DC(pulse)
O
0/5 V DC
O
-
O
24 V DC
I
-
I
3.3 V DC
I
3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC(pulse) Main PFCLK
I
0/3.3 V DC
O
0/3.3 V DC(pulse) PF receiving data
I
24 V DC
I
24 V DC
I
-
O
-
O
3.3 V DC
O
3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC(pulse) Main PFCLK
O
0/3.3 V DC
I
0/3.3 V DC(pulse) PF receiving data
2S0/2S1/2S2/2S3/2S4/2S5/2SG/2SH/3RA
Voltage
24 V DC power output
Paper feed clutch signal
24 V DC power output
Conveying clutch signal
Motor rotation stability signal
motor rotation standard clock
motor rotation start/stop signal
Ground
24 V DC power output
Ground
3.3 V DC power input
3.3 V DC power input
Recovery factor signal
Main PFRDY
PF select signal
PF select signal
PF receiving data
24 V DC power input
24 V DC power input
Ground
Ground
3.3 V DC power output
3.3 V DC power output
Recovery factor signal
Main PFRDY
PF select signal
PF select signal
PF receiving data
8-22