Kyocera ECOSYS M2135dn Service Manual page 400

Hide thumbs Also See for ECOSYS M2135dn:
Table of Contents

Advertisement

Indica-
Contents
tion
6200
Fuser heater error (sub)
During warm-up, the temperature
detected by the thermistor does not
reach 60 ?/212.0 °F when turning
the heater on for consecutive 30s.
During warm-up, the temperature
detected by the thermistor does not
reach the ready temperature when
passing 20s after it reaches 60?/
212°F.
2S0/2S1/2S2/2S3/2S4/2S5/2SG/2SH/3RA-1
Related parts
Check procedures/corrective mea-
Thermopile
1. Reconnect the wire connector
Replace the wire if there is no continu-
ity.
Thermopile - Main/engine PWB (YC2)
2. Replace the thermopile if not repaired
Fuser unit
1. Make sure there is no paper jam.
2. Confirm that the wiring connector is
firmly connected, and if necessary, con-
nect the connector all the way in.
Fuser unit - Main/Engine PWB(YC19)
3. If the wiring is disconnected, short-
circuited or has a ground fault, replace
the wire.
4. If the fuser heater is not turned on
(broken thermostat wire), replace the
fuser unit. (see page 4-17)
Low voltage
1. Confirm that the wiring connector is
power supply
firmly connected, and if necessary, con-
PWB
nect the connector all the way in.
Heater - Low voltage power supply
PWB (YC102)
Low voltage power supply PWB - Main/
Engine PWB(YC20)
2. Replace the low voltage power sup-
ply PWB.
(see page 4-110)
Main/Engine
Replace the main/engine PWB. (see
PWB
page 4-94)