Kyocera ECOSYS M2135dn Service Manual page 335

Hide thumbs Also See for ECOSYS M2135dn:
Table of Contents

Advertisement

* :"Completed" is displayed.
Setting: TX Echo
Sets the time to send the DCS signal after the DIS signal is received. Execute when an error
occurs with echo at the transmitter side.
1.Select the item to set.
Items
500
300
* :Initial setting: 300
2.Press the [Start] key to set the setting value.
* :"Completed" is displayed.
Setting: RX Echo
Sets the time to send the NSF, CSI or DIS signal after the CED signal is received. Execute when
an error occurs with echo at the receiver side.
1.Select the item to set.
Items
500
75
* :Initial setting: 75
2.Press the [Start] key to set the setting value.
* :"Completed" is displayed.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Sends the DCS 500 ms after receiving a DIS.
Sends the DCS 300 ms after receiving a DIS.
Sends the NSF, CSI or DIS 500ms after receiving the CED.
Sends the NSF, CSI or DIS 75ms after receiving the CED.
6-80
2S0/2S1/2S2/2S3/2S4/2S5/2SG/2SH/3RA