Kyocera ECOSYS M2135dn Service Manual page 476

Hide thumbs Also See for ECOSYS M2135dn:
Table of Contents

Advertisement

Connec-
Pin
tor
YC2
1
HUMCLK
2
HUMDATA_
3
TMPDATA
4
GND
5
FUSTMPSE1O
6
GND
7
+3.3V4LS
8
FUSTMPSE1A
9
TPSDA
10
TPSCL
11
GND
12
WTOFULSE
13
+3.3V4LS
YC3
1
+24V6FA
2
GND
3
PMOTREN
4
PMOTRDYN
5
PMOTCLKN
YC5
1
GND
2
+24V6ILFERA
YC6
1
+3.3V2LED
2
GND
3
CASPAPSE
4
+3.3V2LED
5
GND
6
MPFPAPSE
7
GND
8
CMDATA
9
-
YC7
1
+24V6FA
2
FAN2MOTRE
YC8
1
+24V0IL
2
+24V0
Signal
I/O
O
0/3.3 V DC(pulse) Outside machine humidity sensor clock
I
0/3.3 V DC(pulse) Outside machine humidity sensor clock
I
Analog
-
0 V DC
I
Analog
-
0 V DC
-
3.3 V DC
I
Analog
I/O 0/3.3 V DC(pulse) Thermopile I2C communication data
O
0/3.3 V DC(pulse) Thermopile I2C communication clock
-
0 V DC
I
0/3.3 V DC
-
3.3 V DC
-
24 V DC
-
0 V DC
O
0/5 V DC
I
0/3.3 V DC
O
0/5 V DC(pulse)
-
0 V DC
-
24 V DC
-
about1.2 V DC
-
0 V DC
I
0/3.3 V DC
-
about1.2 V DC
-
0 V DC
I
0/3.3 V DC
-
0 V DC
I/O 0/3.3 V DC
-
-
-
24 V DC
I
0/24 V DC
-
24 V DC
-
24 V DC
2S0/2S1/2S2/2S3/2S4/2S5/2SG/2SH/3RA
Voltage
signal
Outside temperature sensor clock signal
Ground
Thermopile output 0
Ground
3.3 V DC power supply
Thermopile output A
Ground
Toner full detection signal
3.3 V DC power supply
24 V DC power source
Ground
Polygon motor drive signal
Polygon motor rotation stability signal
Polygon motor clock
Ground
24 V DC power (When the eraser is off,
the output is turned off.)
Power for PI
Ground
Cassette paper detection
Power for PI
Ground
MPF paper detection
Ground
Container communication
Not used
24 V DC power source
Right side fan drive
24 V DC power (When the cover is
opened, the output is turned off.)
24 V DC power source
8-3
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents