(5-7)Detaching and reattaching the operation panel PWB (TSI model)
Procedures
1. Open the document processor.
2. While lifting up the leading edge, slide
two points of the operation covers (b) in
the direction of the arrow.
3. Detach the operation panel cover (b)
from the operational section (a).
4. Detach the clear panel (b) and (c) from
the operation panel (a).
5. Next detach the operation panel sheet
(d) and (e).