U065
Adjusting the magnification for table scanning
(Message: Adj Scn)
Contents
Adjust the magnification in the sub scanning direction of the table scanning.
Purpose
Adjusts the magnification in the sub scanning direction of the table scanning if the above incor-
rect.
Method
1.Press the [Start] key.
2.Press the [System Menu] key.
3.Place an original and press the [Start] key to make a test copy.
4.Press the [System Menu] key.
5.Select [Sub Scan].
Items
Sub Scan
6.Press the [◄] [►] keys or the numeric keys to change the counter value.
In the case of the copy example 1, raise the setting value.
In the case of the copy example 2, lower the setting value.
* :When the setting value is increased, the image get longer, and it shortens when the setting
value is decreased.
7.Press the [Start] key to set the setting value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Contents
Adjusts scanner magnification in the sub-
scanning direction
Original
example 1
Figure 6-7
2S0/2S1/2S2/2S3/2S4/2S5/2SG/2SH/3RA
Setting range
-25 to 25
Copy
Copy
example 2
6-25
Initial
Data
setting
varia-
tion
0
0.1%