Remote Diag.Set.
Contents
Sets the remote diagnostics
Purpose
Executed to remotely diagnose the main unit from the service center when a problem arises.
Method
1.Enter the Service Setting menu.
2.Using the [▲] [▼] key, select [Remote Diag.Set.].
3.Press the [OK] key.
4.Select [On].
5.Press the [OK] key to set the setting value.
Completion
Select [Exit] by the [Right select] key.
Remote Diag. ID
Contents
Sets the remote diagnostics ID
Purpose
An ID is registered to diagnose the main unit by using the communication from the service center
when a problem arises.
Method
1.Enter the Service Setting menu.
2.Using the [▲] [▼] key, select [Remote Diag. ID].
3.Press the numeric keys to input the pre-designated remote diagnostic ID (0000-9999).
4.Press the [OK] key to set the setting value.
Completion
Select [Exit] by the [Right select] key.
Mem.Diagnostics
Contents
Diagnose memory at power-up (whether reading and writing are executable).
Purpose
The defective memory device may be regarded as one of an unresolvable factor when F-code
error, lock-up or abnormal images occurs. Checks the memory failure.
Method
1.Enter the Service Setting menu.
2.Using the [▲] [▼] key, select [Mem. Diagnostic].
3.Press the [OK] key.
4.Select [Start] by the [Left] key.
5.Turn the power switch off then on. Wait more than 5 seconds between the power off and on.
Completion
Select [Exit] by the [Right select] key.