Kyocera ECOSYS M2135dn Service Manual page 303

Hide thumbs Also See for ECOSYS M2135dn:
Table of Contents

Advertisement

U403
Adjusting margins for scanning an original on the contact
glass
(Message: Adjust Scanning Margin(Table))
Contents
Adjusts the margins for the table scanning.
Purpose
Make the adjustment if margins are incorrect
Adjustment
1.Press the [Start] key.
2.Press the [System Menu] key.
3.Place an original and press the [Start] key to make a test copy.
4.Press the [System Menu] key.
5.Select the item to adjust.
Items
A Margin
B Margin
C Margin
D Margin
6.Press the [◄] [►] keys or the numeric keys to change the counter value.
* :When the setting value is increased, the margin widens, and it narrows when the setting
value is decreased.
7.Press the [Start] key to set the setting value.
Precautions
Check the copy image after the adjustment. If the image is still incorrect, adjust the following in
the maintenance mode.
U034(6-23) > U402(6-47) > U403
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Contents
Adjusts the scanner left margin
Adjusts the scanner leading edge margin. 0.0 to 10.0
Adjusts the scanner right margin
Adjusts the scanner trailing edge margin
Left margin
(Within 4.0mm)
Figure 6-15
2S0/2S1/2S2/2S3/2S4/2S5/2SG/2SH/3RA
Setting range
0.0 to 10.0
0.0 to 10.0
0.0 to 10.0
Leading edge margin
(4.0 +1.5/-0mm)
A
Right margin
(Within 4.0mm)
Trailing edge margin
(Within 4.0mm)
6-48
Initial
Data
setting
varia-
tion
2.0
0.5mm
2.0
0.5mm
2.0
0.5mm
2.0
0.5mm