FUNCTION SETTINGS

5-2-12 Output Operation (

You can select the judgment output operation.
Output operation
Normal Open (N.O.)
Normal Closed (N.C.)
Example of output operation setting (GO output)
HIGH set value
LOW set value
Judgment value
Output operation
Setting method
Long-press for 2 seconds
33
Setting item
Output operation (N.O. / N.C.)
5-26
)
When the judgment is output, ON is output.
When the judgment is output, OFF is output.
CALC: Only appears on master unit
Normal Open (N.O.)
Normal Closed (N.C.)
Function
ON during GO output
OFF during GO output
Set values
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
: Select
: Finalize
Default value
N.O.