5-3-6 Analog Scaling (

The judgment value (JUDGE.V) can be converted to a current (4 to 20mA) and output as ana-
log output.
Analog scaling allows you to select the method of setting the scaling upper limit value and scal-
ing lower limit value for analog output.
Analog scaling
Default (DEFALT)
Free (FREE)
■ When default (DEFALT) is set
The upper limit value varies by sensor head.
The lower limit value is "0.0000", regardless of the sensor head.
Analog current output
20mA
4mA
Lower limit value
Analog output specifications
Current output range
Resolution
Error output
Linearity
Maximum load impedance
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
)
Output an analog current according to the maximum stroke of the sensor head.
You can set the upper limit value and lower limit value of analog output.
To set the upper limit value and lower limit value, refer to "5-3-7 Scaling Upper
Limit Value / Scaling Lower Limit Value".
(0mm)
4 to 20mA
0.3μA
0mA
±0.25% F.S.
250Ω max.
FUNCTION SETTINGS
Function
Judgment value (JUDGE.V)
Upper limit value
(10mm)
5-61