Air Circuit (Recommended) (Air-Driven Type Only) - Panasonic HG-S Series User Manual

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

INSTALLATION AND CONNECTIONS

3-4-5 Air Circuit (Recommended) (Air-Driven Type Only)

<Reference>
Create an air circuit like the one (recommended) shown in the figure below and, if necessary,
adjust the speed of the spindle with the speed control valve.
Air pressure source
Filter + Mist separator + Regulator
Notes: 1) Supply clean air (free from moisture, oil, dust, or other foreign matter) to this product.
2) Air pressure may decrease, depending on the length of the air pipe from the air supply source or any
pneumatic components (such as needle valves, speed controllers, or mini-filters) that are added. Take
care to ensure that air pressure supply to the product is sufficient. Select pneumatic components suit-
able for the supplied air pressure.
3) The 3-port solenoid valve and speed control valve have their respective mounting directions. Mount
each valve in their correct direction by referring to the above diagram.
4) A filter with a rated filtration of 5μm or less and a mist separator with a rated filtration of 0.3μm or less
are recommended.
3-10
3-port solenoid valve
Precision regulator
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
Speed control valve

Advertisement