FUNCTION SETTINGS
Setting item
Measurement mode
(MEAS)
Trigger mode (TRG)
Self trigger level
(SLF.LV)
Self trigger edge direction
(SLF.EDG)
Self trigger delay
(SLF.DLY)
Input all (ALL IN)
Advanced
(Master unit only)
settings
(ADVANC)
External input (EXT.IN)
External output (EXT.OUT)
Number of digits displayed
(DIGIT)
Analog scaling (ANALOG)
Scaling upper limit value
(ANA.HI)
Scaling lower limit value
(ANA.LO)
Eco mode (ECO)
5-8
Static width
(DLY.WD)
Delay timer
(DLY.TIM)
Setting range / set values
You can select the hold mode.
S-H (sample hold) / P-H (peak hold) /
B-H (bottom hold) / P-P (peak to peak hold) / P-P/2 (peak to
peak hold / 2) / NG-H (NG hold) / SLF.S-H (self sample hold) /
SLF.P-H (self peak hold) /
SLF.B-H (self bottom hold)
You can select the external trigger input action.
HOLD (hold) / 1 SHOT (one-shot)
You can use the self (internal) trigger to set the criterion level
for use of the hold function.
-199.9999 to 199.9999
You can use the self trigger level to set the edge direction
used to measure the hold value.
UP (rise) / DOWN (fall)
When using the self sampling hold function, you can set the
self trigger delay type.
DLY.WD (static width) / DLY.TIM (delay time)
You can set the fluctuation width for stabilization that triggers
the start of hold.
0 to 199.9999 (mm)
You can set a delay time for the start of hold.
0 to 9999 (mm)
You can enable ALL IN on the master unit to input trigger
input, preset input, and other signals into all connected slave
units.
ONE (single) / ALL (all)
You can select from four combinations for the signals that
are input into input 1 / input 2 / input 3 of external input.
P/R/T (preset / reset / trigger) /
BANK/P (bank A, B / preset) / BANK/R (bank A, B / reset) /
BANK/T (bank A, B / trigger)
You can select from four combinations for the signals that are
output into output 1 / output 2 / output 3 of external output.
3 VAL (HI, GO, LO) / 2 VAL (HI or LO, INRANGE, ALARM) /
LOGIC (LOGIC, ALARM) / LOGIC2
You can change the number of digits that appear after the
decimal point of the digital display.
0.1 / 0.01 / 0.001 / 0.0001
When the judgment value (JUDGE.V) is converted to a cur-
rent (4 to 20mA) and output as analog output, you can set
the upper limit value and lower limit value.
DEFALT (default) / FREE (free)
When analog scaling is set to "FREE", you can set the upper
limit value of scaling.
-199.9999 to 199.9999 (mm)
When analog scaling is set to "FREE", you can set the lower
limit value of scaling.
-199.9999 to 199.9999 (mm)
You can save power by having the backlight of the controller
display turn OFF when idle.
OFF (Eco OFF) / ON (Eco ON)
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
<Default value: S-H>
<Default value: HOLD>
<Default value: 0.500>
<Default value: UP>
<Default value: DLY.WD>
<Default value: 0.0100>
<Default value: 1000>
<Default value: ONE>
<Default value: P/R/T>
<Default value: 3 VAL>
<Default value: 0.0001>
<Default value: DEFALT>
<Default value: 10.0000>
<Default value: 0.0000>
<Default value: OFF>
Page
5-28
5-29
5-43
5-43
5-43
5-53
5-55
5-57
5-60
5-61
5-63
5-66