■Peak to Peak Hold / 2 (Trigger mode: One-shot)
With respect to normal measured values (NORM.V) during any sampling interval, half the differ-
ence between the peak value (maximum value) and the bottom value (minimum value) is held
as the judgment value (JUDGE.V). The judgment value (JUDGE.V) is updated and held each
time the external trigger input turns ON (rising edge).
Timing chart
Indeterminate until TRIG
input turns ON when
power is turned ON
HIGH set value
LOW set value
B1
Sampling interval
ON
TRIG
indicator
OFF
ON
HOLD
indicator
OFF
Outputs OUT1 / OUT2 / OUT3 according to output setting.
1. When the power is turned ON, the indeterminate state is held until the external trigger input
turns ON.
2. When the external trigger input turns ON (rising edge), half the difference between the mini-
mum value (B1) and maximum value (P1) of normal measured values (NORM.V) that occur
during the sampling interval is held as the judgment value (JUDGE.V).
3. If the reset input turns ON, the indeterminate state is held.
4. Judgment output outputs the judgment result based on the output setting.
* When the calculation function is used, calculation value "CALC" is shown instead of normal
measured value (NORM.V).
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
Normal measured value (NORM.V) *
P2
P1
B2
Sampling interval
FUNCTION SETTINGS
Judgment value (JUDGE.V)
P3
B3
Sampling interval
Indeterminate until TRIG input turns ON after reset
P4
B4
Sampling interval