FUNCTION SETTINGS

5-2-11 Response Time (

You can set the time until the judgment value (JUDGE.V) is finalized (response time) when the
sensor head starts measurement.
The response time setting determines the average count and average time of measurement as
shown below.
Response time (ms)
3
5
10
100
500
1,000
When the Average count is set to 8 times
Sampling cycle (1ms)
Average measurement time (8ms)
<Reference>
● To respond to instantaneous changes, set a shorter response time. To disregard instantaneous
changes, set a longer response time.
● When the reset input is ON, the indeterminate value display shows "
count is reached.
● If the response time is "3" (3ms), the indeterminate value display will show "
5-24
)
Average count
(repetitions)
1
3
8
96
480
960
Internal processing time
Internal processing time(1ms)
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
Average time (ms)
1
3
8
96
480
960
Average over 8 times from 1st time and judge
Average over 8 times from 2nd time and judge
Average over 8 times from 3rd time and judge
Internal value update cycle
(ms)
1
1
1
4
16
32
" until the average