Panasonic HG-S Series User Manual page 81

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

Setting item
Alarm delay count
(DELAY)
Pressure check
(PRS.CHK)
Advanced
Pressure check set value
settings
(PRS.SET)
(ADVANC)
Catch check
(CAT.CHK)
Number of connected
controllers check
(CON.CHK)
(Master unit only)
Calculation mode (MODE)
Calculation
settings
(CALC)
(Master
unit only)
Calculation application se-
lection (APPLI)
Copy select individual
(
Master unit only
Copy select all
Copy
(
Master unit only
settings
Copy execution
(
COPY)
(
Master unit only
Copy lock
(Slave unit only)
Bank
Bank save selection
settings
(BNK.DAT)
(
)
BANK
Calibration selection
(
CAL.SEL
Calibration
Acquired value 1
settings
(
CL.SET1
(
)
CALIB
Acquired value 2
(
CL.SET2
Adjustment value 2
(
AJ.VAL2
Initialization
Initialization
(
)
RESET
Total stroke operation log
Maximum peak value
Maintenance
Maximum peak value opera-
(
)
MAINTE
tion log
Over stroke log
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
You can set the delay count until an alarm is output.
1 to 1000
You can turn the pressure check ON / OFF.
ON (check ON) / OFF (check OFF)
When the pressure check is set to ON, you can set the pres-
sure check set value.
-199.9999 to 199.9999 (mm)
<Regular 10 mm type, air-driven type default value: 10.0000>
You can turn the catch check ON / OFF.
OFF (check OFF) / ON (check ON)
When controllers are connected to the master unit, you can check if
the number connected has changed when the power is turned ON.
OFF (check OFF) / ON (check ON)
You can perform calculation processing based on the
measured values of each of the connected controllers and
display the judgment result on the master unit's display or
output the judgment result from the master unit.
NO.CALC (no calculation) / CALC (calculate)
When calculation mode is set to "CALC", you can select the
application that is used for calculation.
MAX (maximum value) / MIN (minimum value) / FLAT (flat-
ness) / AVERAG (average value) / STAND (standard differ-
ence) / TORSIN (torsion) / CURVEA (curvature) / THICK
(thickness)
(
)
CPY.SEL
You can select individual items to be copied.
)
(
)
CHK.ALL
You can select all items for copying.
)
YES / NO
You can execute copying of individually selected settings or
(
)
CPY.EXE
all settings from the master unit to the slave units.
)
YES / NO
(
)
You can prohibit copying from the master unit.
LOCK
OFF (lock OFF) / ON (lock ON)
You can select the settings in a bank that are read by a bank
read.
THRS (HIGH set value, LOW set value) / THRS.PR (HIGH
set value, LOW set value, preset value) / ALL (all)
You can perform zero-point adjustment and span adjustment
when a sensor head is replaced to reduce installation error.
)
DEFAUL (default) / USER (user settings)
Move the spindle to the zero point for calibration and acquire
)
the measured value.
Move the spindle to the target point for span adjustment and
)
acquire the measured value.
Enter a number for the target value.
)
-199.9999 to 199.9999 (mm)
You can return the controller settings to the factory default
(
)
state.
RESET
YES / NO
(
)
SUM .REC
(
)
MAX. VAL
You can display the sensor head operation log and other in-
formation.
(
)
MAX. REC
(
)
OVR. NUM
FUNCTION SETTINGS
Setting range / set values
<Regular type default value: ON>
<Air-driven type default value: OFF>
<Regular 32 mm type default value: 32.0000>
<Regular 50 mm type default value: 50.0000>
<Default value: NO.CALC>
<Default value: THRS>
<Default value: DEFAUL>
<Default value: 10.000>
<Default value: 1000>
<Default value: OFF>
<Default value: OFF>
<Default value: MAX>
<Default value: YES>
<Default value: YES>
<Default value: OFF>
<Default value: YES>
Page
5-68
5-68
5-72
5-75
5-76
5-78
5-87
5-89
5-90
5-91
5-92
5-94
5-98
5-100
5-9

Advertisement

Table of Contents
loading

Table of Contents