FUNCTION SETTINGS
■ Sample Hold (Trigger mode: One-shot)
Hold is refreshed each time the external trigger input turns ON (rising edge).
Timing chart
HIGH set value
LOW set value
ON
TRIG
indicator
OFF
ON
HOLD
indicator
OFF
Outputs OUT1 / OUT2 / OUT3 according to output setting.
1. When the power is turned ON, the indeterminate state is held until the external trigger input
turns ON.
2. When the external trigger input turns ON (rising edge), the judgment value (JUDGE.V) is held.
3. If the reset input turns ON, the indeterminate state is held.
4. Judgment output outputs the judgment result based on the output setting.
*When the calculation function is used, the calculation value is "CALC".
Setting item
Setting item
Measurement mode
(MEAS)
Setting item
Trigger mode (TRG)
5-30
Judgment value
(JUDGE.V)
Sample hold (S-H)
Peak hold (P-H)
Bottom hold (B-H)
Peak to peak hold (P-P)
Peak to peak hold / 2 (P-P/2)
NG hold (NG-H)
Self sample hold (SLF.S-H)
Self peak hold (SLF.P-H)
Self bottom hold (SLF.B-H)
Hold (HOLD)
One-shot (1SHOT)
Set values
Set values