Panasonic HG-S Series User Manual page 140

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

FUNCTION SETTINGS
■ Pressure Check / Pressure Check Set Value / Alarm Delay Count
If the spindle is pressed in too far, sensor head damage may result.
By turning ON pressure check, an alarm is output to help pprevent sensor head damage.
When the sensor head value exceeds the pressure check set check value, an alarm is output
after sampling cycle (1ms) × alarm delay count time.
By adjusting the alarm delay count, you can prevent alarm output due to instantaneous pres-
sure changes.
Pressure
check threshold
value
Outputs HI / GO / LO according to the output setting.
5-68
HEAD.V
Alarm not output because recovered
within alarm delay count
Alarm delay count
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
Alarm