Panasonic HG-S Series User Manual page 109

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

■ Bottom Hold (Trigger mode: One-shot)
When the external trigger input turns ON, the bottom value during the sampling interval (external
trigger input OFF interval) is held as the judgment value (JUDGE.V). When the external trigger
input turns OFF, the next sampling interval starts.
Timing chart
Indeterminate until TRIG
input turns ON when
power is turned ON
HIGH set value
LOW set value
Sampling interval
ON
TRIG
indicator
OFF
ON
HOLD
indicator
OFF
Outputs OUT1 / OUT2 / OUT3 according to output setting.
1. When the power is turned ON, the indeterminate state is held until the external trigger input
turns ON.
2. When the external trigger input turns ON (rising edge), the minimum normal measured value
(NORM.V) that occurs during the sampling interval is held as the judgment value (JUDGE.V).
3. If the reset input turns ON, the indeterminate state is held.
4. Judgment output outputs the judgment result based on the output setting.
* When the calculation function is used, calculation value "CALC" is shown instead of normal
measured value (NORM.V).
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
Normal measured value (NORM.V) *
Minimum value (bottom value)
during sampling interval
Sampling interval
FUNCTION SETTINGS
Judgment value (JUDGE.V)
Sampling interval
Indeterminate until TRIG input turns ON after reset
Sampling interval
5-37