<Reference>
● When self peak hold or self bottom hold is selected, external trigger input is invalid.
● When a sensor head not connected error or pressure alarm / error is cleared, the same action
as a reset takes place.
● The judgment value (JUDGE.V) is held in the same way in the measurement modes of self bot-
tom hold.
Setting items
Trigger mode (TRG)
●
The hold action during the sampling interval can be set.
• When "HOLD" is selected, the peak value is updated whenever necessary during the sam-
pling interval.
• When "1SHOT" is selected, the peak value is held during the sampling interval as well.
Setting item
Trigger mode (TRG)
Self trigger level (SLF.LV)
●
You can set the level that starts stabilization diagnosis of the normal measured value (NORM.V).
Setting item
Self trigger level (SLF.LV)
Self trigger edge direction (SLF.EDG)
●
You can set the edge direction for triggering of the self trigger.
Setting item
Self trigger edge direction (SLF.EDG)
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
Set values / setting range
Hold (HOLD)
One-shot (1SHOT)
Set values / setting range
-199.9999 to 199.9999 (mm)
Set values / setting range
Rise (UP)
Fall (DOWN)
FUNCTION SETTINGS
Default value
HOLD
Default value
0.5000
Default value
UP
5-51