5-2-5 Tolerance <±> (
When performing 1-point teaching, you can set a value equal to the master workpiece judgment
value (JUDGE.V) plus a tolerance as the HIGH set value, and a value equal to the master work-
piece judgment value minus a tolerance as the LOW set value.
HIGH set value
Midpoint of allowed value
LOW set value
<Reference>
● The tolerance setting (±) is only valid when 1-point teaching is ON.
● For the 1-point teaching method, refer to "4-2-3 Teaching Mode".
Setting method
Long-press for 2 seconds
Setting
Tolerance (±) (TOL<±>)
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
)
CALC: Only appears on master unit
Finalize
0 to 199.9999
FUNCTION SETTINGS
+1.000
When tolerance <±> = 1.000
-1.000
Master workpiece
: Move through digits
: Change value
Setting range
Default value
0.1000
5-17