4-3-2 Statuses and Measures

The statuses judged by the self-monitoring function are classified into the following four categories.
When the status is "notification", "caution", or "fault", you must check the installation state or
maintain or replace the product.
Status
Normal
Normal state
Notification Unstable detection state
Caution
State in which the device must be replaced
Fault
State in which the device is uncontrollable
If "notification", "caution", or "fault" status is displayed, take measures as shown in the following table.
Response parameter
Sensor head unconnected
Connected unit count check error
NPN / PNP output types mixture error
Calculated unlit count error
Notifi-
cation
Copying was executed but it failed be-
cause the slave unit was abnormal
The thrust on the sensor head
stroke is above the specified range.
Pressure check
Catch check
Controller memory function damaged
Sensor head memory function dam-
aged
Fault
Output section short-circuit error
Detection circuit damaged
System error
Note1: Error codes and measurement alarms are displayed on HG-SC□ controllers.
Note2: This product does not have "Caution" information.
<Reference>
● For details on how to read each status, refer to the user's manual of the communication unit SC-
HG1 series (except the SC-HG1-USB) that you use.
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
Description
Measures
Status check
Status check
Status check
Status check
Status check
Status check
Status check
Status check
Controller
replacement
Sensor head re-
placement
Status check / Re-
placement
Sensor head re-
placement
Controller
replacement
BASIC OPERATION
Remarks
The device is operating normally.
Review the settings.
The device has almost reached its service life.
The device is short-circuited or broken.
Error code(Note1)
E200
E160(For master
units only)
E100(For master
units only)
E110(For master
units only)
E170(For master
units only)
E210
E600 / E610 / E620
E630
E700
E240
E900 / E910 / E911 /
E912 / E920
Measurement
alarm(Note1)
Alarm
Alarm
4-27