Hysteresis - Panasonic HG-S Series User Manual

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

5-2-3 Hysteresis (

If the judgment value fluctuates near the HIGH or LOW set value, the judgment output may re-
peat ON / OFF and operation may become unstable. Operation can be stabilized by increasing
the hysteresis value.
When the hysteresis is "0"
Fluctuation of the judgment value (JUDGE.V) near the HIGH set value (or LOW set value)
will cause the judgment output to become unstable.
HIGH set value
LOW set value
Judgment value
When a hysteresis is set
By setting a hysteresis, the judgment output will remain stable even if the judgment value
(JUDGE.V) fluctuates near the HIGH set value (or LOW set value).
HIGH set value
LOW set value
Judgment value
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
)
Fluctuates near HIGH set value or LOW set value
HIGH
GO
LOW
Fluctuates near HIGH set value or LOW set value
HIGH
GO
LOW
Not stable
Stable
FUNCTION SETTINGS
Hysteresis
Hysteresis
5-13