5-2. Response Time Change Function

Response time can be switched among four levels:
H-SP (ultra high-speed) / FAST (high-speed) / STD
(standard) / U-LG (ultra long-range).
* The incident light intensity display can display a
maximum value of 4,000 in H-SP (ultra high-speed)
mode and FAST (high-speed) mode. In STD
(standard) mode and U-LG (ultra long-range) mode, it can display up to a maximum value of 9,999.
* In H-SP mode, the interference prevention / copy / single step load / single step save functions cannot be used.
After making settings in H-SP mode and using the copy function or another function in a different mode, turn the
power off and then back on again.
H-SP
FAST
(ultra high-speed)
(high-speed)
Select the desired response time
by turning the Jog switch.
The digital display will quickly
blink to confirm the setting.
Press the
MODE key 5 times.
Turn the Jog switch once
toward the '
' direction.
Press the
Jog switch.
Press the
Jog switch.
STD
U-LG
(standard)
(ultra long-range)
Press the
Jog switch.
Press the
MODE key once.
Press the
MODE key once.
Setting
(ultra high-speed)
(high-speed)
(standard)
(ultra long-range)
1Press the [MODE key] 5 times to select 'PRO mode'.
2Turn the [Jog switch] once toward the '
'PRO1 mode'.
3Press the [Jog switch] to enter the 'response time change'
state.
4If the [Jog switch] is pressed, the current response time (red)
will be displayed.
* The factory setting is 'STD (standard)'.
5If the [Jog switch] is turned, response time (red) will blink on
the digital display.
Select the desired response time.
6If the [Jog switch] is pressed, response time (red) will quickly
blink on the digital display and the selected 'response time'
will be confirmed.
The digital display will not blink (red) if the setting has not
been changed.
* The receiving light sensitivity will be set to the maximum
setting for the mode being set.
7If the [MODE key] is pressed once, the amplifier will return to
'PRO1 mode'.
8Press the [MODE key] once, the amplifier will return to 'RUN
mode' (normal sensing operation).
25
Response time
80!s (0.08 ms) or less
150!s (0.15 ms) or less
500!s (0.5 ms) or less
4 ms or less