Interrupt, error and system messages
9.1 PROFIBUS DP
Diagnostics with the IM 153-2BAx2
The IM 153-2 interface module (order number 6ES7153-2BAx2-0XB0 and higher) supplies
the same diagnostics information as the existing IM 153-2 interface module. The maximum
length of the diagnostics is now 130 bytes. Due to the 12 available slots, the IM 153-2BAx2
has a partially expanded diagnostic structure. In addition, the length of the diagnostic
interrupt has been expanded.
The following changes have been made in the diagnostics:
● The identifier-related diagnostics information comprises 3 bytes, same as previously.
● The module status is 1 byte longer and now comprises 8 bytes. Slots 12 to 15 now
● The diagnostic interrupt can have a maximum of 63 bytes.
192
Byte 8 contains an additional 4 bits for the new slots (slots 12 to 15).
contain 2 new bits each.