Aligning The Ethernet Adapter Port Connectors; Side View Of Adapter In The Server; Port Connector Alignment - IBM Storwize V7000 Unified Problem Determination Manual

Table of Contents

Advertisement

Ethernet
adapter connector
Figure 16. Aligning the Ethernet adapter port connectors with the port openings
11. Slide the port connectors on the adapter into the port openings on the chassis;
Ethernet ports
Chassis
Rubber
stopper
Figure 17. Side view of adapter in the server
Figure 18. Port connector alignment
116
Storwize V7000 Unified: Problem Determination Guide Version
1
Standoff
2
then, press the adapter firmly until the two standoffs engage the adapter.
Make sure the adapter is securely seated on the connector on the system
board.
Make sure the port connectors on the adapter do not set on the rubber
stopper. The following illustration shows the side view of the adapter in the
server.
Adapter
System board
Attention: Make sure the port connectors on the adapter are aligned
properly with the chassis on the rear of the server. An incorrectly seated
adapter might cause damage to the system board or the adapter.