IBM Storwize V7000 Unified Problem Determination Manual page 150

Table of Contents

Advertisement

11. Run the file module for 4 to 6 hours to fully charge the controller battery.
12. When you restart the file module, import the existing RAID configuration to
Removing a hot-swap hard disk drive
The following procedure is for a Tier 1 customer replaceable unit (CRU).
Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at
your request, you will be charged for the installation. Service agreements can be
purchased so that you can ask IBM to replace these units.
About this task
To remove a hard disk drive from a hot-swap bay, complete the following
procedure.
Procedure
10. During the node shutdown period, replace the hard disk drive in slot 2 of the
11. Turn on the node by pressing the flashing power on/off button on the front of
126
Storwize V7000 Unified: Problem Determination Guide Version
initializes the battery. This might take a few minutes, after which the startup
process continues. This is a one-time occurrence.
The battery comes partially charged, at 30% or less of capacity. The LED just
above the battery on the controller remains lit until the battery is fully
charged.
Until the battery is fully charged, the controller firmware sets the controller
cache to write-through mode; after the battery is fully charged, the controller
firmware re-enables write-back mode.
the new ServeRAID SAS controller at the prompt.
1. To help you work safely with Storwize V7000 Unified file module, read the
safety information in "Safety" on page xi, "Safety statements" on page xiii,
and "Installation guidelines" on page 58.
2. Press up on the release latch at the top of the drive front.
3. Rotate the handle on the drive downward to the open position.
4. Note the orientation of the drive as you pull the hot-swap drive assembly
from the bay so you will know which way to orient the new drive you will be
installing in the same bay.
5. If you are instructed to return the hot-swap drive, follow all packaging
instructions, and use any packaging materials for shipping that are supplied
to you.
6. To repair the third hard disk drive (in slot 2) of a management node, open the
RAS menu by clicking Application > Unified RAS Menus.
7. Click Unified RAS Menus > Managment Node Menus > Repair /ftdc (3rd)
Hard Drive.
#=============================================================================#
# SONAS RAS Menus
active@mgmt001st001
# |->Management Menus ...
#=============================================================================#
# 1. Show List of Management Role Nodes and CTDB status
# 2. Show List of Management Role Nodes and CTDB status (with refresh)
# 3. Repair /ftdc (3rd) Hard Drive
#
# B. Back
# E. Exit
#=============================================================================#
Choice: 3
8. Select the management node with the bad hard disk drive.
9. If you are ready to replace the hard disk drive, respond yes to the prompts,
which shuts down the management node.
management node.
the node.
#
#
#
#
#
#
#
#