Vrm Led Is Lit; Dasd Led Is Lit - Avaya Aura S8800 Maintaining

Server for sip enablement services
Hide thumbs Also See for Aura S8800:
Table of Contents

Advertisement

Troubleshooting
2. Replace the server if the microprocessor has failed.
3. Make sure that the microprocessors are compatible with each other if the

VRM LED is lit

The VRM LED on the light path diagnostics panel is not used.
Troubleshooting steps
Procedure
Ignore unless directed otherwise by Avaya.

DASD LED is lit

The DASD LED on the light path diagnostics panel is lit when a hard disk drive fails or is
missing.
Troubleshooting steps
Procedure
1. Check the LEDs on the hard disk drives for the drive with a lit status LED and reseat
2. If the error remains, replace the hard disk drive and then restart the server.
Related topics:
Hard disk drive LEDs
Hard disk drive LEDs
Removing a hard disk drive
68
Maintaining the Avaya S8800 Server for Avaya Aura
• If the CNFG LED is lit, then an invalid microprocessor configuration has
occurred.
microprocessor configuration is invalid.
The microprocessors must match in speed and cache size. To compare the
microprocessor information, run the Setup utility and select System Information >
System Summary > Processor Details.
the hard disk drive.
on page 25