Avaya Aura S8800 Maintaining page 44

Server for sip enablement services
Hide thumbs Also See for Aura S8800:
Table of Contents

Advertisement

Diagnostics LEDs
4. Reseat the failing PCIe card.
5. Replace the server.
Related topics:
Removing a PCIe card
Installing a PCIe card
Removing a PCIe card
Installing a PCIe card
SP LED is lit
The SP LED on the light path diagnostics panel is lit when an error occurs on the service
processor.
Troubleshooting steps
Procedure
1. Remove power from the server; then, reconnect the server to power and restart the
2. Report this error to your service provider for possible server replacement.
FAN LED is lit
The FAN LED on the light path diagnostics panel is lit when a fan fails, is operating too slowly,
or has been removed. The TEMP LED might also be lit.
Troubleshooting steps
Procedure
1. Reseat the failing fan, which is indicated by a lit LED near the fan connector on the
2. Replace the server.
TEMP LED is lit
The TEMP LED on the light path diagnostics panel is lit when the system temperature exceeds
a threshold level. A failing fan can cause the TEMP LED to be lit.
44
Maintaining the Avaya S8800 Server for Avaya Aura
server.
system board.