Light path diagnostics panel

Light path diagnostics panel
1
2
3
4
Maintaining the Avaya S8800 Server for Avaya Aura
light path diagnostics panel must remain in the server when the server is running
to ensure proper cooling.
on page 41
Remind button
This button places the system-error LED on the front panel into Remind
mode. In Remind mode, the system-error LED flashes once every 2
seconds until the problem is corrected, the server is restarted, or a new
problem occurs.
By placing the system-error LED indicator in Remind mode, you
acknowledge that you are aware of the last failure but will not take
immediate action to correct the problem. The remind function is controlled
by the Integrated Management Module (IMM).
NMI button
Pressing this button forces a nonmaskable interrupt to the microprocessor.
You might have to use a pen or the end of a straightened paper clip to press
the button. Use this button only when directed by your service provider.
Checkpoint code display
The checkpoint code is an internal code used for IBM development only
and is subject to change over time. The checkpoint code does not provide
error codes or suggest components to be replaced. Ignore this code unless
you have a specific request from Avaya to note it .
Reset button
Pressing this button resets the server and runs the power-on self-test
(POST). You might have to use a pen or the end of a straightened paper
clip to press the button. The Reset button is in the lower-right corner of the
light path diagnostics panel.
®